Tie connectors for large panel construction
Intended use
Tie connectors for large panel construction are intended for connecting the internal and external wythes of insulated sandwich wall panels.Design
The tie connector for large panel construction comprises the following elements:For the use in a bearing panel:
- BFRP bar with a uniform sand coating,
- Plastic restrainer,
- Stainless steel collar.
- BFRP bar with a uniform sand coating,
- Plastic restrainer.
Tie connectors with a restrainer installed at 90° - designed for fixing reinforced concrete wythes and thermal insulation against each other as well as for taking compressive and tensile loads caused by wind and other impacts acting perpendicularly to a facade surface.
Marking
BPA 300-60-6-P-90, where BPA – BFRP bar; 300 – tie connector length, mm; 60 – distance from the end of the tie connector to the plastic restrainer, mm; 6 – bar diameter, mm; P – bar sand coating; 90 – restrainer installation angle, angle degree. | BPA-V 420-90-6-P-45, where: BPA – BFRP bar; V – tie connector with stainless steel collar; 420 – tie connector length, mm; 90 – distance from the end of the tie connector to the plastic restrainer, mm; 6 – bar diameter, mm; P – bar sand coating; 45 – restrainer installation angle, angle degree. |
Technical characteristics of tie connectors with collars
Tie connector length | from 120 to 500 mm |
Diameter | 6 mm |
Minimal anchorage length | 30 – 35 mm |
Ultimate tensile strength, not less than | 1000 MPa |
Ultimate bending strength, not less than | 1000 MPa |
Tensile modulus, not less than | 50 GPa |
Collar-wall tie bond strength, not less than | 15 MPa |
Compressive modulus | 30 GPa |
Pull-out strength from concrete, not less than | 4000 N |
Tensile strain, not more than | 3 % |
Thermal conductivity coefficient | 0,46 W/M*°C |
Pull out strength from concrete
Test conditions | Pull-out strength from concrete, kN | |
BFRP tie connectors with steel collars (TU 5714-022-13101102-2014) | Standard BFRP tie connectors (TU 5714-006-13101102-2009) | |
Diagonally installed tie connectors | ||
 15 (anchorage depth 80 mm) | 5.45 | Not less than 6 kN in standard conditions (B25 concrete grade, anchorage depth 80 mm) |
 20 (anchorage depth 80 mm) | 6.43 | |
 25 (anchorage depth 80 mm) | 7.3 | |
Vertically installed tie connectors | ||
 30 (anchorage depth 40 mm) | 4.95 | Not less than 5 kN in standard conditions (B25 concrete grade, anchorage depth 80 mm) |
 30 (anchorage depth 60 mm) | 7.18 |
Regulatory documents
- Technical specifications «Composite tie connectors for three layer reinforced concrete panels» TU 5714-022-13101102-2014;
- Technical Approval ÒS ¹ 4736-15;
- Certificate of conformance with Nanocertifica requirements ¹ ÐÎÑÑ RU.È750.HÆ02.000161;
- Certificate of conformance with Nanocertifica requirements ¹ ÐÎÑÑ RU.È750.HÆ04.000010.